我们有一个带有 P410 RAID 卡的 DL180 G6 服务器。服务器具有以下三个 RAID 阵列。
4x2TB - RAID 10
4x2TB - RAID 10
2x2TB - RAID 1
2x2TB HD 配置为三个阵列的热备件。
以下是 ESXCLI 的相关输出
插槽 1 中的智能阵列 P410
Bus Interface: PCI
Slot: 1
Serial Number: PACCR9VYJKGQ
Cache Serial Number: PAAVP9VYJCYN
RAID 6 (ADG) Status: Enabled
Controller Status: OK
Hardware Revision: C
Firmware Version: 2.72
Rebuild Priority: Medium
Expand Priority: Medium
Surface Scan Delay: 15 secs
Surface Scan Mode: Idle
Parallel Surface Scan Supported: No
Queue Depth: Automatic
Monitor and Performance Delay: 60 min
Elevator Sort: Enabled
Degraded Performance Optimization: Disabled
Inconsistency Repair Policy: Disabled
Wait for Cache Room: Disabled
Surface Analysis Inconsistency Notification: Disabled
Post Prompt Timeout: 0 secs
Cache Board Present: True
Cache Status: OK
Cache Ratio: 25% Read / 75% Write
Drive Write Cache: Disabled
Total Cache Size: 512 MB
Total Cache Memory Available: 400 MB
No-Battery Write Cache: Disabled
Cache Backup Power Source: Batteries
Battery/Capacitor Count: 1
Battery/Capacitor Status: OK
SATA NCQ Supported: True
Number of Ports: 2 Internal only
Driver Name: HP HPSA
Driver Version: 6.0.0
PCI Address (Domain:Bus:Device.Function): 0000:06:00.0
Host Serial Number: USE626N2XD
Sanitize Erase Supported: False
Primary Boot Volume: None
Secondary Boot Volume: None
Secondary Boot Volume: None
阵列 A(SATA,未使用空间:0 MB)
logicaldrive 1 (3.6 TB, RAID 1+0, OK)
physicaldrive 1I:1:9 (port 1I:box 1:bay 9, SATA, 2 TB, OK)
physicaldrive 1I:1:10 (port 1I:box 1:bay 10, SATA, 2 TB, OK)
physicaldrive 1I:1:11 (port 1I:box 1:bay 11, SATA, 2 TB, OK)
physicaldrive 1I:1:12 (port 1I:box 1:bay 12, SATA, 2 TB, OK)
physicaldrive 1I:1:5 (port 1I:box 1:bay 5, SATA, 2 TB, OK, spare)
physicaldrive 1I:1:6 (port 1I:box 1:bay 6, SATA, 2 TB, OK, spare)
阵列 B(SATA,未使用空间:0 MB)
logicaldrive 2 (3.6 TB, RAID 1+0, OK)
physicaldrive 1I:1:1 (port 1I:box 1:bay 1, SATA, 2 TB, OK)
physicaldrive 1I:1:2 (port 1I:box 1:bay 2, SATA, 2 TB, OK)
physicaldrive 1I:1:3 (port 1I:box 1:bay 3, SATA, 2 TB, OK)
physicaldrive 1I:1:4 (port 1I:box 1:bay 4, SATA, 2 TB, OK)
physicaldrive 1I:1:5 (port 1I:box 1:bay 5, SATA, 2 TB, OK, spare)
physicaldrive 1I:1:6 (port 1I:box 1:bay 6, SATA, 2 TB, OK, spare)
阵列 C(SATA,未使用空间:0 MB)
logicaldrive 3 (1.8 TB, RAID 1, OK)
physicaldrive 1I:1:7 (port 1I:box 1:bay 7, SATA, 2 TB, OK)
physicaldrive 1I:1:8 (port 1I:box 1:bay 8, SATA, 2 TB, OK)
physicaldrive 1I:1:5 (port 1I:box 1:bay 5, SATA, 2 TB, OK, spare)
physicaldrive 1I:1:6 (port 1I:box 1:bay 6, SATA, 2 TB, OK, spare)
现在在 ESXI 中,我们不时会收到以下错误。
由于连接问题,无法访问卷 5456cb3e-4fbdb59c-a37a-d8d385644ec0 (datastore2)。正在进行恢复尝试
请记住,它会同时影响所有三个阵列,并且在几秒钟内所有三个阵列都会恢复。据了解,所有驱动器都连接到 P410 RAID 卡上的一个端口。您是否认为使用这两个端口可以提高性能并有可能消除这个反复出现的问题?
此时我们已经尝试了所有软件解决方案,包括更新固件(更新到 6.64)。还有什么其他选择?
更新 1
如上所述,两个备用驱动器被配置为所有三个阵列的备用驱动器。我从所有阵列中移除了大约 15 分钟的备件,并且错误停止了。现在我已经为第一个阵列配置了第一个备用,为第二个阵列配置了第二个备用,以查看错误是否再次出现。
更新 2
重新连接备件导致错误返回,并且影响所有三个阵列。因此,我将一一移除备件以进一步解决此问题。这可能是此处描述的已知问题:http: //community.hpe.com/t5/ProLiant-Servers-ML-DL-SL/ESXi5x-HPSA-P410i-WARNING-LinScsi-SCSILinuxAbortCommands-1843/td-p/6818369 . 手指交叉。