当我通过以下方式转储 LSI RAID 9260-8i 配置时:
/storcli /c0 show all
该Supported VD Operations
部分如下所示:
Read Policy = Yes
Write Policy = Yes
IO Policy = Yes
Access Policy = Yes
Disk Cache Policy = Yes
Reconstruction = Yes
Deny Locate = No
Deny CC = No
Allow Ctrl Encryption = No
Enable LDBBM = Yes
Support FastPath = Yes
Performance Metrics = Yes
Power Savings = No
Support Powersave Max With Cache = No
Support Breakmirror = No
Support SSC WriteBack = Yes
Support SSC Association = Yes
Support VD Hide = No
Support VD Cachebypass = No
Support VD discardCacheDuringLDDelete = No
那里的SSC WriteBack
表达是什么意思?